construction image here
  Healthcare ESD

Consistent
Stable conductivity
Superior Stain-Resistance

STATICPULSE™ ESD Control Vinyl Tile is the ultimate solution to today’s technological environments where static electricity is more than the annoying nuisance of a simple shock.

Electrostatic discharges can damage or degrade sensitive electronic components, ignite flammable gases, and cause equipment malfunction.

STATICPULSE™ ESD solves this problem protecting your valuable equipment while still giving the looks and performance you've come to expect from LG.

 

APPLICATIONS

  • Clean Rooms
    STATICPULSE™ ESD Control Vinyl Tile meets requirements in clean rooms as strict as class 10 based on its high-tech know-how by over 700 research and manufacturing staff. It has no free carbon to contaminate the clean room, and low outgassing emissions and is independent of room temperature and humidity. It is highly suitable for special clean room maintenance techniques, Semiconductor, Microelectronics, Optics, Aerospace, Pharmaceutics, Biotechnology, etc.
  • Access Flooring
    STATICPULSE™ ESD Control Vinyl Tile is suitable for use on access flooring. It can easily be perforated without risk of rough edges or the tile cracking or breaking. Major manufacturers of raised or access flooring are experienced in the use of STATICPULSE™ ESD Control Vinyl Tile.
  • Healthcare
    STATICPULSE™ ESD Control Vinyl Tile removes static discharge to prevent data errors that may occur with high-tech visual medical equipment such as CT SCAN, MRI, or other sensitive equipment.
  • Electronics Manufacturing Assembly, Test Areas
    STATICPULSE™ ESD Control Vinyl Tile is a permanently installed material that helps protect sensitive electronic devices, assemblies, and products from personnel-generated electrostatic discharge.
  • Computer and Electronic Equipment and
    Telecommunications Environments

    STATICPULSE™ ESD Control Vinyl Tile controls static discharges into computer terminals and other sensitive electronic equipment, thus preventing damage to internal circuitry, incorrect entries or retrieval, loss of computer memory or other malfunction. It protects large data processing facilities, computerized typesetting and drafting equipment, process control equipment, communications installations, and other static sensitive equipment and instruments.

Easy Maintenance

Our easy to maintain high-performance polyurethane top layer means STATICPULSE™ will survive soil, stains and scuffs much better! Easy maintenance means lower costs associated with keeping your floor clean!

Product Specifications

STATICPULSE™
PHYSICAL DATA
Electrical / Electrostatic Properties
ITEM STANDARD TEST METHOD ASTM SPEC CONDUCTIVE TILE STATIC DISSIPATIVE TILE
Electrical Resistance ESD S 7.1 (100V) 2.5 x 104~106 2.5 x 104~106 106~108
Electrical Resistance
(Surface to Surface)
ASTM F-150 (100V) 2.5 x 104~106 2.5 x 104~106 106~108
NFPA 99 (500V) 2.5 x 104~106 2.5 x 104~106 (SD: 106~109)
Electrical Resistance
(Surface to Ground)
DIN 51953 (500V) <2.5 x 104~106 <2.5 x 104~106 106~108
Electrostatic Propensity
(Static Generation)
ESD STM 97.2 N/A Less than 20 volts Less than 20 volts
Static Decay Federal Test Method 101B Method 4046 at 15% Relative Humidity < 0.5 sec 0.01 sec 0.01 sec
Other Properties
CEN Classification DIN EN 685   Class 34 + 43
Composition of Material ASTM F 1700,
Certificate of Compliance
  Homogeneous
Thickness ASTM F 386,
DIN EN 428
as specified ± 0.005 in (0.13mm) 1/8", 2mm
Nominal Sizes ASTM F 536,
DIN EN 427
± 0.01 in./lin. Ft (0.4mm / 304.8mm) 12 x 12", 24 x 24", 36 x 36"
Squareness ASTM F 540 maximum 0.010in. (0.25mm) < 0.010"
Residual Indentation ASTM F1914,
DIN EN 433
average less than 8%,
max. single reading 10%
< 7%
Flexibility ASTM F 137 no crack or break no crack or break
Dimensional Stability ASTM Fed. Std. No. 501a, Method 6211, DIN EN 434 < 0.020"/ft (0.51mm / 304.8mm) < 0.015"/ft
Resistance to Chemicals ASTM F 925,
DIN EN 423
No more than a slight change in surface dulling, surface attack, or staining No more than a slight change in surface dulling, surface attack, or staining
Resistance to Heat ASTM F 1514 ∆E < 8 ave., max < ∆E = 2.0
Resistance to Light ASTM F 1515 ∆E < 8 ave., max < ∆E = 2.0
Static Load Limit Modified ASTM F 970-00   2,500 psi
Smoke Density ASTM E 662 < 450 < 450
Flame Spread ASTM E 84,
NFPA 225
< 75 < 75
Fire Resistance DIN 4102   B1
Critical Radiant Flux ASTM F 648,
NFPA 253
  > 1.08 W/cm2 (class I Interior Floor Finish, NFPA Life Satety Code 101)
Abrasion Resistance ASTM D 1044,
CS-10-F Wheel,
500Gm Weight
  Cycle 10,000,
% Gauge Loss - 1.60
Resistance to Wear DIN EN 660-1   M
Effect of Castor Chair DIN EN 425   No damage
Color Fastness ISO 105 B02   At least 6
Standard fo Health NFPA 99   Confirms to the requirement
Care Facilities     of NFPA 99 in effect at the time of installation
Fulfills product requirements DIN EN 649   Yes
Underwriters Laboratories UL 779   Meets UL Standard

 


Environmental DataEnvironmental data

  Need environmental data here...