Consistent
Stable conductivity
Superior Stain-Resistance
STATICPULSE™ ESD Control Vinyl Tile is the ultimate solution to today’s technological environments where static electricity is more than the annoying nuisance of a simple shock.
Electrostatic discharges can damage or degrade sensitive electronic components, ignite flammable gases, and cause equipment malfunction.
STATICPULSE™ ESD solves this problem protecting your valuable equipment while still giving the looks and performance you've come to expect from LG.
APPLICATIONS
- Clean Rooms
STATICPULSE™ ESD Control Vinyl Tile meets requirements in clean rooms as strict as class 10 based on its high-tech know-how by over 700 research and manufacturing staff. It has no free carbon to contaminate the clean room, and low outgassing emissions and is independent of room temperature and humidity. It is highly suitable for special clean room maintenance techniques, Semiconductor, Microelectronics, Optics, Aerospace, Pharmaceutics, Biotechnology, etc. - Access Flooring
STATICPULSE™ ESD Control Vinyl Tile is suitable for use on access flooring. It can easily be perforated without risk of rough edges or the tile cracking or breaking. Major manufacturers of raised or access flooring are experienced in the use of STATICPULSE™ ESD Control Vinyl Tile. - Healthcare
STATICPULSE™ ESD Control Vinyl Tile removes static discharge to prevent data errors that may occur with high-tech visual medical equipment such as CT SCAN, MRI, or other sensitive equipment. - Electronics Manufacturing Assembly, Test Areas
STATICPULSE™ ESD Control Vinyl Tile is a permanently installed material that helps protect sensitive electronic devices, assemblies, and products from personnel-generated electrostatic discharge. - Computer and Electronic Equipment and
Telecommunications Environments
STATICPULSE™ ESD Control Vinyl Tile controls static discharges into computer terminals and other sensitive electronic equipment, thus preventing damage to internal circuitry, incorrect entries or retrieval, loss of computer memory or other malfunction. It protects large data processing facilities, computerized typesetting and drafting equipment, process control equipment, communications installations, and other static sensitive equipment and instruments.
Easy Maintenance
Our easy to maintain high-performance polyurethane top layer means STATICPULSE™ will survive soil, stains and scuffs much better! Easy maintenance means lower costs associated with keeping your floor clean!
Product Specifications
PHYSICAL DATA | ||||
---|---|---|---|---|
Electrical / Electrostatic Properties | ||||
ITEM | STANDARD TEST METHOD | ASTM SPEC | CONDUCTIVE TILE | STATIC DISSIPATIVE TILE |
Electrical Resistance | ESD S 7.1 (100V) | 2.5 x 104~106Ω | 2.5 x 104~106 | 106~108 |
Electrical Resistance (Surface to Surface) |
ASTM F-150 (100V) | 2.5 x 104~106Ω | 2.5 x 104~106 | 106~108 |
NFPA 99 (500V) | 2.5 x 104~106Ω | 2.5 x 104~106Ω | (SD: 106~109) | |
Electrical Resistance (Surface to Ground) |
DIN 51953 (500V) | <2.5 x 104~106Ω | <2.5 x 104~106Ω | 106~108 |
Electrostatic Propensity (Static Generation) |
ESD STM 97.2 | N/A | Less than 20 volts | Less than 20 volts |
Static Decay | Federal Test Method 101B Method 4046 at 15% Relative Humidity | < 0.5 sec | 0.01 sec | 0.01 sec |
Other Properties | ||||
CEN Classification | DIN EN 685 | Class 34 + 43 | ||
Composition of Material | ASTM F 1700, Certificate of Compliance |
Homogeneous | ||
Thickness | ASTM F 386, DIN EN 428 |
as specified ± 0.005 in (0.13mm) | 1/8", 2mm | |
Nominal Sizes | ASTM F 536, DIN EN 427 |
± 0.01 in./lin. Ft (0.4mm / 304.8mm) | 12 x 12", 24 x 24", 36 x 36" | |
Squareness | ASTM F 540 | maximum 0.010in. (0.25mm) | < 0.010" | |
Residual Indentation | ASTM F1914, DIN EN 433 |
average less than 8%, max. single reading 10% |
< 7% | |
Flexibility | ASTM F 137 | no crack or break | no crack or break | |
Dimensional Stability | ASTM Fed. Std. No. 501a, Method 6211, DIN EN 434 | < 0.020"/ft (0.51mm / 304.8mm) | < 0.015"/ft | |
Resistance to Chemicals | ASTM F 925, DIN EN 423 |
No more than a slight change in surface dulling, surface attack, or staining | No more than a slight change in surface dulling, surface attack, or staining | |
Resistance to Heat | ASTM F 1514 | ∆E < 8 ave., max | < ∆E = 2.0 | |
Resistance to Light | ASTM F 1515 | ∆E < 8 ave., max | < ∆E = 2.0 | |
Static Load Limit | Modified ASTM F 970-00 | 2,500 psi | ||
Smoke Density | ASTM E 662 | < 450 | < 450 | |
Flame Spread | ASTM E 84, NFPA 225 |
< 75 | < 75 | |
Fire Resistance | DIN 4102 | B1 | ||
Critical Radiant Flux | ASTM F 648, NFPA 253 |
> 1.08 W/cm2 (class I Interior Floor Finish, NFPA Life Satety Code 101) | ||
Abrasion Resistance | ASTM D 1044, CS-10-F Wheel, 500Gm Weight |
Cycle 10,000, % Gauge Loss - 1.60 |
||
Resistance to Wear | DIN EN 660-1 | M | ||
Effect of Castor Chair | DIN EN 425 | No damage | ||
Color Fastness | ISO 105 B02 | At least 6 | ||
Standard fo Health | NFPA 99 | Confirms to the requirement | ||
Care Facilities | of NFPA 99 in effect at the time of installation | |||
Fulfills product requirements | DIN EN 649 | Yes | ||
Underwriters Laboratories | UL 779 | Meets UL Standard |
Environmental Data